Introduction and Features of CMC-MX Series Built-in Bypass Soft Starter

CMC-MX built-in bypass soft starter introduction:

CMC-MX built-in bypass motor soft starter is a voltage-regulating and current-limiting intelligent asynchronous motor soft starter based on trigger closed-loop algorithm. Superior power electronic circuit detection and advanced closed-loop control algorithm make the starting and protection functions more perfect. . The built-in bypass contactor contacts use magnetically held contactors, which are different from other external bypass AC contactors for long-term live operation. This product has no noise, no electromagnetic pollution, no sparks, and is environmentally friendly.

CMC-MX built-in bypass soft starter function:

It can smoothly start/stop the motor without stepping, avoiding mechanical and electrical shocks caused by starting the motor in the traditional starting mode such as direct start, star/delta start, auto-decompression start, etc., and can effectively reduce the start-up. Current and distribution capacity to avoid capacity expansion. At the same time, the CMC-MX soft starter integrates current transformers and contactors, and the user does not need to connect externally.

CMC-MX built-in bypass soft starter model description:

CMC-MX built-in bypass soft starter features:

1, a variety of starting methods

The user can select current-limit start, voltage ramp start, and can apply programmable kick start and start current limit in each mode. Maximize the needs of the site to achieve the best start-up effect.

2, high reliability

The high-performance microprocessor digitizes the signals in the control system, avoiding the excessive adjustment of analog lines in the past, resulting in excellent accuracy and execution speed.

3, strong anti-interference

All external control signals are optically isolated and have different levels of noise immunity for use in special industrial environments.

4, simple adjustment method

The control system has a wide range of applications, and the mode adjustment is simple and intuitive. Various function options can be used to match various control objects.

5. Optimized structure

The unique compact internal structure design makes it easy for users to integrate into existing systems, saving users the cost of current transformers and bypass contactors.

6, power frequency adaptation

The power frequency 50/60Hz adaptive function is convenient for users.

7, analog output

4-20mA current output function, convenient for users.

8, MODBUS-RTU communication

When network communication is performed, 32 devices can be connected. The user can set the baud rate and communication address to achieve the purpose of automatic communication. The communication address setting range is 1-32 and the factory default is 1. The communication baud rate setting range is: 0, 2400; 1, 4800; 2, 9600; 3, 19200; the factory default is 2 (9600).

9, perfect protection function

A variety of motor protection functions (such as overcurrent, input and output phase loss, thyristor short circuit, overheat protection, leakage detection, electronic thermal overload, internal contactor failure, phase current imbalance, etc.) to ensure that the motor and soft starter are malfunctioning or malfunctioning. It is not damaged.

10, easy to maintain

The monitoring signal coding system consists of 4-digit digital display, which monitors the working condition of the system equipment 24 hours and provides fast fault diagnosis.

CMC-MX built-in bypass soft starter conditions:

Control power supply AC110V--220V±15%, 50/60Hz three-phase power standard wiring AC380V

Internal triangle wiring AC380V±30% nominal current 15A--560A, a total of 18 kinds of ratings for motors General squirrel cage AC asynchronous motor starting ramp mode current limiting soft start, voltage ramp start parking mode free stop, soft stop logic input impedance 1.8KΩ, power +15V starting frequency can be frequently or infrequently started. It is recommended to start no more than 10 times per hour. Protection function phase failure, over current, short circuit, SCR protection, overheating, underload, phase current imbalance, wiring, Internal faults and other protection levels IP00, IP20 cooling mode natural cooling or forced air cooling installation method wall-mounted environmental conditions over 2000 meters, should reduce the capacity

Ambient temperature between -25-+45 °C

The corresponding humidity does not exceed 95% (20 °C ± 5 °C)

No flammable, explosive, corrosive gas, no conductive dust, indoor installation, good ventilation, vibration less than 0.5G

Water-cooled Capacitor

Water-cooled capacitor is supercapacitor is a capacitor with a capacity of thousands of farads.According to the principle of capacitor, capacitance depends on the distance between the electrode and electrode surface area, in order to get such a large capacitance, as far as possible to narrow the distance between the super capacitor electrode, electrode surface area increased, therefore, through the theory of electric double layer and porous activated carbon electrode.

Water-Cooled Capacitor,Water-Cooled Power Capacitor,Water-Cooled Electric Heat Capacitor,Water-Cooled Electric Heating Capacitor

YANGZHOU POSITIONING TECH CO., LTD. , https://www.yzpst.com

Posted on